Northwestern University engineers have developed a small, wireless polygraph system you can wear.

Unlike polygraphs used in television crime dramas, this wearable version isnโ€™t optimized to detect lies. Instead, engineers and physicians designed it to sense underlying stress hidden deep within the body โ€” no interrogation room required.

The lightweight, bandage-like device gently adheres to the chest, where it simultaneously measures heart activity, breathing patterns, sweat response, blood flow and temperature. Together, these signals capture a real-time, whole-body view of stress.

By continuously tracking multiple physiological signals at once, the device could help clinicians detect stress and potential discomfort in patients โ€” including infants or the elderly โ€” who may be unable to communicate, diagnose sleep disorders without cumbersome in-laboratory equipment, monitor mental health over time and even sense early warning signs of medical complications.



โ€œSometimes, the body manifests signs of stress before a person is consciously aware of it,โ€ said Northwesternโ€™s John A. Rogers, who led the device development. โ€œEven if people donโ€™t realize how much pressure they are under, stress is quietly affecting their health. Prolonged stress can have adverse consequences, especially for pregnant mothers, children and critically ill patients. An ability to track stress based on quantitative measurements could empower people to take stress-relieving actions with direct benefits to their health. Importantly, we aimed to design a device, conceptually like a polygraph system, that operates on the basis of biophysical body responses, without requiring access to chemical biomarkers found in body fluids.โ€

A world-renowned bioelectronics pioneer, Rogers is the Louis Simpson and Kimberly Querrey Professor of Materials Science and Engineering, Biomedical Engineering and Neurological Surgery at Northwestern, where he has appointments in the McCormick School of Engineering and Northwestern University Feinberg School of Medicine. He also directs the Querrey Simpson Institute for Bioelectronics and the Querrey Simpson Institute for Translational Engineering and Advanced Medical Systems. Rogers is co-corresponding author of the study along with Dr. Debra E. Weese-Mayer, the Beatrice Cummings Mayer Professor of Pediatric Autonomic Medicine and professor of pediatrics (neurology) at Feinberg and Jae-Young Yoo of Sungkyunkwan University in Korea.

A voice for the vulnerable

The project started as a request from pediatricians at Ann & Robert H. Lurie Childrenโ€™s Hospital of Chicago. Over the years, Rogersโ€™ team has developed a suite of wireless, wearable electronics for infants and children โ€” to track vital signsmonitor illnesstreat congenital conditions and diagnose disease. Now, pediatricians asked Rogers to create a soft, non-invasive device to detect and continuously track stress levels in babies throughout hospital stays, without measuring stressโ€™ biochemical signatures in saliva and blood.

Currently, detecting babiesโ€™ stress often depends on what caregivers can see and hear โ€” crying, facial expressions and movement โ€” along with basic vital signs. But these signals can be subtle, inconsistent or even entirely absent.

โ€œStress is often scored using survey sheets and nursing assessments,โ€ Rogers said. โ€œThe entries include things like tonality and volume of crying. Infants obviously cannot describe their own pain levels. So, unlike with adults, determining stress in babies can be incredibly challenging. We wanted to take subjectivity out of these assessments.โ€

โ€œThis new device tracks the bodyโ€™s stress signals around the clock, helping quantify how long someone is stressed each day and how intense that stress is,โ€ said Weese-Mayer, Rogersโ€™ long-time collaborator. โ€œThe beauty of the device is that both individuals and healthcare providers can now identify stress and objectively monitor the effectiveness of interventions to decrease stress and restore a healthy balance, in a completely non-invasive manner.โ€

All-in-one stress sensing

To do that, Rogers and his team found inspiration in a surprising place: polygraphs. Although they are colloquially called โ€œlie detectors,โ€ polygraphs actually donโ€™t detect lies. They measure the bodyโ€™s response to stress, which can be triggered by many factors besides deception. Rogers saw an opportunity to build on that core idea. But, while traditional polygraph machines rely on a patchwork of bulky, wired sensors, Rogers aimed to capture those same physiological signals โ€” and then some โ€” in a more comprehensive, fully integrated, accurate and wearable form.

The resulting technology combines several tiny sensors into a single, soft device. Together, these sensors continuously track multiple physiological signals, all of which respond when the body senses stress. A built-in motion sensor and miniature microphone capture subtle mechanical and acoustic signals from the heart and lungs. Other sensors detect skin temperature and heat flow associated with near-surface blood circulation. And another sensor measures changes in the skinโ€™s electrical conductivity caused by sweat gland activity โ€” a well-known marker of stress.

โ€œMeasuring stress is a complex task because itโ€™s multi-dimensional,โ€ Rogers said. โ€œItโ€™s not possible to reliably determine stress by measuring just one or two, or even three or four, parameters. A broad collection of factors is necessary. So, we crammed as many sensors of physiological processes into this device platform as we could, while maintaining a compact size and lightweight construction and avoiding the need to access biofluids.โ€

The system wirelessly transmits these synchronized data streams to a smartphone, smart watch or tablet, where machine learning algorithms analyze patterns associated with stress in real time. Weighing less than 8 grams (equivalent to eight paperclips) and designed to move naturally with the skin, the device can operate continuously for more than 24 hours.

Proven across realistic scenarios

After developing the system, Rogersโ€™ team validated it across a wide range of scenarios, including controlled experiments and real-world environments. During simulated lie-detector tests, the wearable device accurately captured stress responses triggered by sensitive questions and closely matched measurements from commercial polygraph systems. 

In cognitive tests, such as understanding speech in noisy environments, the device detected clear increases in stress-related signals as tasks increased in difficulty. The results aligned with simultaneous, independent measurements of pupil dilation, a common method to determine stress. 

In another experiment, study participants placed their hands in ice-cold water, and the system recorded coordinated changes across cardiac activity, breathing patterns, sweat responses and temperature signals. In pediatric sleep studies, the wearable device identified key clinical events, including breathing irregularities and nighttime awakenings, with accuracy comparable to hospital-grade sleep tests but with far fewer disruptions. 

And, finally, during emergency room training sessions with medical students, the device revealed a striking pattern. Participants with stronger stress responses tended to perform worse, suggesting stress may impair decision-making in high-pressure situations.

โ€œUltimately, the device could send an alert to a user or caregiver when stress levels hit a certain limit,โ€ Rogers said. โ€œMany people might not fully appreciate the level of stress they are under and might not realize itโ€™s affecting their performance.โ€

Whatโ€™s next

Next, the team aims to move its technology beyond validation studies and into broader clinical use. Next steps will include testing the device in larger patient groups, refining its ability to personalize stress detection and integrating it into hospital and at-home monitoring systems to provide continuous, real-time insight into patient health. 

Rogers also is exploring opportunities for incorporating even more sensors into the device, including the ability to measure brain activity. Adding electroencephalogram (EEG) capabilities would allow the device to move beyond measuring the bodyโ€™s stress response to capturing how the brain perceives that stress. That could bring scientists closer to distinguishing stress from pain โ€” even in the home setting โ€” and understanding how it is experienced in the context of the simultaneously recorded stress biomarkers.

โ€œWe are living in stressful times, without sufficient measures to proactively detect stress,โ€ Weese-Mayer said. โ€œBy identifying stress โ€” whether environmental or disease-induced โ€” earlier, we can introduce intervention before stressโ€™ effects become irreversible.โ€

The study, โ€œWireless, skin-interfaced multimodal sensing system for continuous psychophysiological monitoring โ€” a wearable polygraph device,โ€ was supported by the Querrey Simpson Institute for Bioelectronics.

IMAGE CREDIT: John A. Rogers/Northwestern University.


Red meat: Evolutionโ€™s double-edged sword
Red meat, pivotal in human evolution, is now seen as a health …
The first domesticated horses: 6,000 years of a complex story
Domestication of horses was a gradual, complex process influencing human history through …

Leave a Reply

Trending

Discover more from Scientific Inquirer

Subscribe now to keep reading and get access to the full archive.

Continue reading